Maxim-integrated Analog Essentials Getting Started Guide for LX9 an Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Maxim-integrated Analog Essentials Getting Started Guide for LX9 an herunter. Maxim Integrated Analog Essentials Getting Started Guide for LX9 and Nexys3 User Manual [pl] [en] [cs] [de] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 23
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Analog Essentials
Getting Started Guide
1
For LX9 and Nexys-3
Overview
Maxim Analog Essentials are a series of plug-in peripheral modules that allow engineers to quickly test, evaluate, and
integrate Maxim components into their hardware/software designs. The modules electrically and physically conform to
the Digilent Pmodinterface specification and are compatible with any Digilent Pmod-compatible header.
The Analog Essentials collection contains 15 peripheral module boards which are supported by prebuilt hardware and
software projects for various FPGA development boards which are compatible. This version of the Getting Started Guide
is applicable to LX9 and Nexys™-3 boards, both of which are based on Spartan®-6 FPGAs. Users of the other FPGA boards
should refer to different versions of this guide.
Important notesplease read carefully
1. ESD Sensitivity. These modules are intended to be used in an electronic prototyping setting.
They are sensitive to static charge and are subject to damage if proper precautions against
ESD are not taken. When handling these modules, the user should take the same care and
precautions as when working with other ESD sensitive prototypes.
2. Plug Connector mating. Many plug-in modules contain only one row of six pins, while most Pmod connectors
contain two rows of six contacts each. When plugging in a module with a single row of pins, always plug the
module into the top row of contacts.
3. Plug in with care. Please exercise care when plugging the modules into the Pmod port. The connectors are not
keyed, so it is possible to incorrectly plug in the module and misalign the pins. Although each module includes
series resistors to provide current limiting, in some cases it is still possible to damage the module if it is
incorrectly plugged in.
4. Nexys-3 and LX9 Differences. Most of the instructions in this document refer to both the Nexys-3 board and the
LX9. Instances where a procedure is specific to one board or other will be denoted by the following indicators:
Additional components required
Interested users may wish to obtain additional components to evaluate the following modules:
MAX3231MPMB1this module requires a 10mm, 3V lithium primary type coin cell. The generic battery type is CR1025.
Specific examples of this battery are Panasonic #CR1025 and Energizer #CR1025.
MAX31855PMB1this module requires a K-Type thermocouple with subminiature connector. Omega series 5SRTC are
suitable (
www.omega.com). Lower cost alternatives may be available via eBay.
Seitenansicht 0
1 2 3 4 5 6 ... 22 23

Inhaltsverzeichnis

Seite 1 - Overview

Analog Essentials Getting Started Guide 1 For LX9 and Nexys-3 Overview Maxim Analog Essentials are a series of plug-in peripheral modules that all

Seite 2

Analog Essentials Getting Started Guide 10 For LX9 and Nexys-3 4. Using Xilinx SDK/XMD to download and run executable file (.elf) on the Microbla

Seite 3

Analog Essentials Getting Started Guide 11 For LX9 and Nexys-3 5. Running the demonstration programs Peripheral modules can now be placed into t

Seite 4 - Getting Started

Analog Essentials Getting Started Guide 12 For LX9 and Nexys-3 The remaining sections of this document are intended to serve only as brief outline

Seite 5

Analog Essentials Getting Started Guide 13 For LX9 and Nexys-3 c. Make an edit to the maximPMOD.c file. We will uncomment a line of code to add a

Seite 6

Analog Essentials Getting Started Guide 14 For LX9 and Nexys-3 2. Optional: Setting the memory locations and generating a linker script In small

Seite 7

Analog Essentials Getting Started Guide 15 For LX9 and Nexys-3 b. [ LX9 version. Skip to step “c” for Nexys-3.] This will bring up the linker scr

Seite 8

Analog Essentials Getting Started Guide 16 For LX9 and Nexys-3 c. [ Nexys-3. See above for LX9] This will bring up the linker script menu as show

Seite 9

Analog Essentials Getting Started Guide 17 For LX9 and Nexys-3 Detailed Steps: Opening the ISE Project to View the HDL and Launch EDK 1. Open Xil

Seite 10 - Analog Essentials

Analog Essentials Getting Started Guide 18 For LX9 and Nexys-3 c. Once any changes are made, the project can be rebuilt by selecting Generate Pro

Seite 11

Analog Essentials Getting Started Guide 19 For LX9 and Nexys-3 2. Open the EDK/XMP project (Microblaze Core/Peripherals) a. Highlight and double

Seite 12

Analog Essentials Getting Started Guide 2 For LX9 and Nexys-3 Analog Essentials Collection modules The table below lists the peripheral modules in

Seite 13

Analog Essentials Getting Started Guide 20 For LX9 and Nexys-3 d. This will launch a dialog box asking to export the design or export and launch

Seite 14

Analog Essentials Getting Started Guide 21 For LX9 and Nexys-3 Appendix A: Project Notes 1. Each active Pmod port has a dedicated I2C port, SPI

Seite 15

Analog Essentials Getting Started Guide 22 For LX9 and Nexys-3 Appendix B: Project Structure and Key Filenames

Seite 16

Analog Essentials Getting Started Guide 23 For LX9 and Nexys-3 All trademarks are property of their respective owners.

Seite 17

Analog Essentials Getting Started Guide 3 For LX9 and Nexys-3 Typical System Architecture Below is a generalized block diagram for the architectur

Seite 18

Analog Essentials Getting Started Guide 4 For LX9 and Nexys-3 Getting Started Introduction With small Microblaze FPGA designs, it is typical for t

Seite 19

Analog Essentials Getting Started Guide 5 For LX9 and Nexys-3 Detailed Steps: Downloading the Example/Demonstration Application 1. Opening the SD

Seite 20

Analog Essentials Getting Started Guide 6 For LX9 and Nexys-3 d. Review the SDK IDE. The Project Explorer in the upper left tab should have three

Seite 21

Analog Essentials Getting Started Guide 7 For LX9 and Nexys-3 2. Downloading the bitstream (.bit) file to the board. a. Click on the Program FPG

Seite 22

Analog Essentials Getting Started Guide 8 For LX9 and Nexys-3 It takes approximately 10 seconds to download the FPGA and a message box indicating

Seite 23

Analog Essentials Getting Started Guide 9 For LX9 and Nexys-3 3. Setting Up the PC for Communication Before loading the executable software file

Kommentare zu diesen Handbüchern

Keine Kommentare