Maxim-integrated 78M6610+LMU Evaluation Kit Bedienungsanleitung Seite 10

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 9
78M6610+LMU Evaluation Kit User Manual
10 Rev 1
3.2.1 Jumper Position Changes
Move J23 and J24 jumpers to position CT to use CT2 for sensor slot S1.
J23 Jumper Description
J23 Pins
Description
Jumper
1/2 Connect J15 SHUNT to 78M6610+LMU Sensor Slot 1 -
2/3 Connect J10 CT2+ to 78M6610+LMU Sensor Slot 1 Installed
J24 Jumper Description
J24 Pins Description Jumper
1/2 Connects J8 SHUNT to 78M6610+LMU Sensor Slot 1 -
2/3 Connects J10 CT2- to 78M6610+LMU Sensor Slot 1 Installed
J9 Jumper Description
J9 Pins
Description
Jumper
1/2 Connect AC Neutral to V3P3A (chip reference) Installed
3.2.2 Device Configuration
Use the Configuration tab to map the sensors as shown in the table below. Re-enter the gain value as needed
for CT2 into the S1_GAIN register.
Voltage
Current
VA
S0
IA
S1
0
VB
0
S2
IB
0
S3
VC
S0
-S2
Pre-Amp
1X S1
1X S3
Note: The values for VC will not be displayed correctly on the Power tab of the provided GUI due to the
increased full-scale value of VC. Reported results for measurements derived from VC will be one-half the
expected magnitude.