Figure 4. This screen capture illustrates how to configure the MAX6876 for mixed-mode
tracking/sequencing.
7. Consult Table 1 and select the appropriate options for each channel.
Table 1. Channel-Control Options.
Option
Name
Function
100 Ohm
Pull Down
Activates a 100Ω pulldown resistor on the channel's OUT connection during shutdown only.
Overcurrent
Threshold
Activates overcurrent monitoring on the channel. This compares the IN_ voltage to the OUT_
voltage. When OUT_ falls below a percentage of IN_, Overcurrent Threshold asserts the OC
output (bringing it low).
Assert
RESET
Activates this channel's control over the RESET line. If this channel falls below its power-
good threshold, RESET asserts low.
Power
Good
Threshold
When the channel's OUT voltage is within this percentage of the IN voltage, the
corresponding PG pin asserts (goes high impedance).
Kommentare zu diesen Handbüchern