MAXQ Family User’s Guide:
MAXQ8913 Supplement
16-2
The first byte output by this command is the value 160 (0A0h), which represents the number of peripheral register
words output. Table 16-1 lists the remaining 352 bytes output by this command. Values shown as “—” are don’t care
values that should be ignored by the debugging host.
Table 16-1. Output from DebugReadMap Command
x0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF
0x
PO0 PO1 EIF0 EIE0 EIF1 EIE1 SVM —
1x
PI0 PI1 EIES0 EIES1 PWCN PID0 — —
2x
PD0 PD1 — — — — — —
3x
— — — — — — — —
4x
SCON — SPICN — I2CCN I2CST — I2CIE
5x
SMD PR SPICF SPICK I2CCK I2CTO I2CSLA —
6x
— — — — — — — —
7x
— — — — — — — —
8x
MCNT MA MB MC2 MC1 MC0 TBCN TBR
9x
MC1R MC0R TBV TBC — — — —
Ax
— — — — — — — —
Bx
— — — — — — — —
Cx
ADST ADADDR DAC1OUT DAC2OUT DAC3OUT DAC4OUT AMPCN ISINKCN
Dx
ADCN — OPMCN DACEN TEMPEN — — —
Ex
— — — — — — — —
Fx
— — — — — — — —
10x
— — — — — — — —
11x
— — — — — — — —
12x
AP APC PSF IC IMR SC IIR CKCN WDCN 00 A[0] A[1] A[2]
13x
A[3] A[4] A[5] A[6] A[7] A[8] A[9] A[10]
14x
A[11] A[12] A[13] A[14] A[15] IP SP+1 IV
15x
LC[0] LC[1] OFFS DPC GR BP DP[0] DP[1]