Table 3-5 shows the input range for various PGA settings (PGG2:PGG0) in unipolar mode. When the PGA is used (gain > 1), the dif-
ferential input range at the analog multiplexer input is reduced by the gain factor. The maximum PGA output value is limited to 3.2V.
For gain > 1, differential input range x PGA gain ≤ 3.2V and the ADC output code range is limited to 0–2621 (decimal).
Table 3-5. Unipolar Input Scaling
The MAXQ7665/MAXQ7666 ADC output is two’s complement in bipolar mode. Figure 3-6 shows the MAXQ7665/MAXQ7666 ADC bipo-
lar transfer function for PGA gain = 1. Table 3-6 shows the bipolar relationship between the differential analog input voltage and the
digital output code for PGA gain = 1. In bipolar mode, the inputs are measured in a truly differential fashion where either input can
exceed the other by up to REFADC/2 (for gain = 1, but limited for gain > 1).
(1.6V max)
(0.8V max)
(0.4V max)
(0.2V max)
(0.1V max)